Product Categories
- Marine Cable
- Marine Power Cable
- Marine Communication Cable
- Marine Control Cable
- Offshore Cable
- Crane Cable
- Mining Cable
- Electrical Cable
- Solar Cable
- Underwater Cable
- Wind Cable
Applications:
This product is used in ships,petrol platforms and offshore buildings for power,light and control systems,usually used for fixed installation in most areas and open deck in ships.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended..
Constructions:
1.Conductor
Stranded copper wire 1.0mm2 to 10mm2 Class 2
Annealed stranded copper wire on request.
2.Insulation
XLPE
3.Bedding
Separate tape
4.Sheath
Polyolefine Plastic(SHF1)
Applied Standards:
Design | IEC 60092-376 |
Conductor | IEC 60228 Class 2 |
Insulation | IEC 60092-351 |
Sheath | IEC 60092-359 |
Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
Halogen-free | IEC 60754 series |
Smoke emission | IEC 61034 series |
Service Conditions
1.Rated Voltage:U0/U 250/350V
2.long time working temperature 90℃
3.Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C
4.flexible cables for mobile devices,the other cables are fixed laying
cable bending radius while laying is as below
Cable Structure | Cable Outer Diameter | Minimum Bending Radius |
Metal Braided Armored | 6D | |
Non Armored | D≤25 | 4D |
D>25 | 6D |
Certifications:
Our marine cable has been type approved by the following Classification Societies