Cable for Submersible Water Pump

Flat Cable for Submersible Water Pump

Flat Cable for Submersible Water Pump

Application:

This cable is intended for use with submersible pumps and irrigation equipment. For wiring only between equipment located at water wellheads and motors of submersible pumps installed in deep wells.As connection cable for submersible electric motors (pumps) for the permanent use in potable water up to temperature of 70 °C and to a depth of 600 m. The cable is resistant to chlor- and sea water,liquid manor,moreover for use in dry, damp and wet rooms with medium mechanical load. Test certificates of different national and international institutes are available on request.

Construction

conductor material:bare copper wire IEC 60228/DIN VDE 0295
conductor construction:fine stranded, class 5
insulation:rubber EI7
sheathing material:rubber (CR) 5GM3

Special PVC Compound Insulated and sheathed submersible cable can be produced as per Customer requested. 

Technical Data

flame retardant: VDE 0482-332-1-2/IEC 60332-1
conductor maximum temperature at:90 °C
max. operating temperature,
fixed:-40 – +90 °C
temperature, moved/during installation:-40 – +90 °C
Submersible pump cable (-J)/ Submersible pump cable (-O)
nominal voltage : 450/750 V 600/1000V
test voltage: 2.5 kV 3.5KV
core identification: colours acc. VDE 0293 (HD308)

Specifications

Code Name Number of Conduc
-tors in Cable
Ground Wire Size (AWG) Size AWG Stranding (Al/Stl) Diameter Complete Cable (OD) Weight Per 1000ft Total (Lbs) Allow
-able Amp
-acity 30C (Amps)
Inches Mils
4/3 W/GRND Hydroflex Pump 3 N/A 4 412 x 001 143 x 067 364 x 170 806 95
2/3 W/GRND Hydroflex Pump 3 N/A 2 259 x 00159 165 x 072 418 x 182 1209 130
1/0-3 W/GRND Hydroflex Pump 3 N/A 1/0 414 x 00159 198 x 087 504 x 221 1867 170
2/0-3 W/GRND Hydroflex Pump 3 N/A 2/0 522 x 00159 213 x 092 540 x 233 2172 195
3/0-3 W/GRND Hydroflex Pump 3 N/A 3/0 734 x 00159 224 x 102 570 x 269 2569 230
4/0-3 W/GRND Hydroflex Pump 3 N/A 4/0 829 x 00159 236 x 114 600 x 290 2842 260
250-3 W/GRND Hydroflex Pump 3 N/A 250 973 x 00159 293 x 133 746 x 339 3894 290
350-3 W/GRND Hydroflex Pump 3 N/A 350 361 x 00159 315 x 141 800 x 358 5106 350
500-3 W/GRND Hydroflex Pump 3 N/A 500 1921 x 00159 374 x 156 951 x 397 6920 430
4/3 W/GRND Hydroflex Pump 3 6 4 412 x 001 183 x 067 464 x 170 1118 95
2/3 W/GRND Hydroflex Pump 3 5 2 259 x 00159 204 x 072 518 x 182 1470 130
1/0-3 W/GRND Hydroflex Pump 3 3 1/0 414 x 00159 254 x 087 644 x 221 2270 170
2/0-3 W/GRND Hydroflex Pump 3 2 2/0 522 x 00159 275 x 092 698 x 233 2710 195
3/0-3 W/GRND Hydroflex Pump 3 1 3/0 734 x 00159 301 x 102 778 x 269 3240 230
4/0-3 W/GRND Hydroflex Pump 3 1/0 4/0 829 x 00159 339 x 114 860 x 290 3615 260
250-3 W/GRND Hydroflex Pump 3 2/0 250 973 x 00159 392 x 133 996 x 339 4990 290
350-3 W/GRND Hydroflex Pump 3 3/0 350 361 x 00159 422 x 141 1072 x 358 6450 330
500-3 W/GRND Hydroflex Pump 3 250 500 1921 x 00159 483 x 156 1228 x 397 8533 430

SELECTION GUIDE FOR 3 CORE FLAT CABLES :
CABLES SELECTION CHART AT 400 C. 415 V. (WITH DOL STARTER)

Submersible Motors Size of Cable in Sq.mm at Different Length in Mtrs.
H.P. Full Load Current Amps. 30 40 50 60 70 80 90 100 110 130 140 180
5 7.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 4 4
7.5 11 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 4 6
10 15 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6
12.5 19 2.5 2.5 2.5 2.5 4 4 4 4 6 6 10 10
15 22.5 4 4 4 4 4 4 4 6 6 10 10 10
17.5 26 4 4 4 4 4 6 6 6 10 10 10 10
20 28.4 6 6 6 6 6 6 6 6 10 10 10 16
25 35.6 10 10 10 10 10 10 10 10 10 10 16 16
30 42.3 10 10 10 10 10 10 10 10 10 16 16 16
35 50.4 16 16 16 16 16 16 16 16 16 16 25 25
40 58.1 16 16 16 16 16 16 16 16 16 16 25 25
45 62.1 25 25 25 25 25 25 25 25 25 25 25 25
50 67.5 25 25 25 25 25 25 25 25 25 25 25 35
55 73.8 35 35 35 35 35 35 35 35 35 35 35 35
60 81.0 35 35 35 35 35 35 35 35 35 35 35 35
65 87.3 35 35 35 35 35 35 35 35 35 35 35 35
70 93.6 50 50 50 50 50 50 50 50 50 50 50 50
75 100.8 50 50 50 50 50 50 50 50 50 50 50 50
80 108.0 50 50 50 50 50 50 50 50 50 50 50 50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLES SELECTION CHART AT 400 C. 415 V. ( WITH STAR DELTA STARTER – DOUBLE CABLE )

Submersible Motors Size of Cable in Sq.mm at Different Length in Mtrs.
H.P. Full Load Current Amps. 30 40 50 60 70 80 90 100 110 130 140 180
5 7.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5
7.5 11 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 4 4 4
10 15 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 4 6 6
12.5 19 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 6 6 6
15 22.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6 10
17.5 26 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6 10
20 28.4 2.5 2.5 2.5 4 4 4 4 6 6 10 10 10
25 35.6 4 4 4 4 4 4 6 6 10 10 10 16
30 42.3 4 4 4 4 6 6 6 10 10 10 10 16
35 50.4 6 6 6 6 6 6 6 10 10 10 16 16
40 58.1 10 10 10 10 10 10 10 10 10 16 16 16
45 62.1 10 10 10 10 10 10 10 10 10 16 16 16
50 67.5 10 10 10 10 10 10 10 10 16 16 16 25
55 73.8 10 10 10 10 10 10 10 10 16 16 16 25
60 81.0 16 16 16 16 16 16 16 16 16 25 25 25
65 87.3 16 16 16 16 16 16 16 16 16 25 25 25
70 93.6 16 16 16 16 16 16 16 16 16 25 25 35
75 100.8 16 16 16 16 16 16 16 16 16 25 25 35
80 108.0 25 25 25 25 25 25 25 25 25 25 25 35