Product Categories
- Marine Cable
- Marine Power Cable
- Marine Communication Cable
- Marine Control Cable
- Offshore Cable
- Crane Cable
- Mining Cable
- Electrical Cable
- Solar Cable
- Underwater Cable
- Wind Cable
TUV UV Resistant PV1-F Solar Cable Applications
Applied to solar panels for power generation and related components of the wiring, connection,particularly suitable for outdoor . Resistance to sunlight, anti-aging , Using the low smoke halogen-free flame retardant materials, higher grade, more safety .
TUV UV Resistant PV1-F Solar Cable Executive Standard:
PV cable( Solar Photovoltaic Cable ) refers to original draft made out by PV system cable work team of German Standard Committee(Technical Specification 2PFG1169/08.2007 in Rhein TUV company German).
1, Rated voltage:
AC: U0 / U = 0.6/1kV
DC: 1.8kV (line core for core, non-grounded systems, no load circuit)
If the cable is used in the DC system, the rated voltage between the conductors of the cable should not exceed 1.5 times the AC rating of U.
In the single-phase DC systems, this value should be multiplied by the factor 0.5. Operating temperature -40 °C ~ 90 °C (with> 25 years)
2, ambient temperature: -40 °C to +90 °C
Maximum conductor operating temperature: 120 °C
Cable runs ambient temperature up to 90 °C. According to EN60216-1 standard for assessment, the insulation and jacket temperature index is 120 °C.
The life expectancy is 25 years
The short-circuit temperature is 5 seconds 200 °C
3, the short-circuit temperature +280 °C
4, does not melt under high temperature, no flow
5, high flame, through the vertical flame test
6, heat, cold, abrasion, UV, ozone, hydrolysis
7, has good mechanical strength, water,oil and chemical resistance
Cable Characteristics
MODEL | PV1-F |
Conductor | Tinned copper wire,class 5 (as per IEC 60228) |
Insulation | No Halogen PO insulation |
Sheath | No Halogen PO sheath |
rated voltage | AC 0.6/1KV |
DC 1.8KV | |
Temperature range | -40°C~+90°C,dry/ humidity |
Max.working temperature of conductor | 120°C |
During short circuit | 200°C |
Standard | EN 2PFG 1169 |
PV1-F Structure Parameter
type | Cross Sectional Area(mm2) |
Conductor structure ( Strand /mm) |
diameter (mm) |
insulation thickness (mm) |
sheath thickness (mm) |
cable diameter (mm) |
DC resistance at 20°C (Ω/km) |
PV1-F | 4 | 56/0.3 | 2.6 | 1.0 | 0.9 | 6.4 | 4.7 |
PV1-F | 6 | 84/0.3 | 3.2 | 1.0 | 0.9 | 7.0 | 3.11 |
Current Capacity Reference Value
(Ambient Temperture:60°C,Max. Conductor Working Temperature:120°C)
Nom.Area(mm2) | Single core in the air(A) | Single core on the equipmnt surface(A) | Next to equipment(A) |
4 | 55 | 52 | 44 |
6 | 70 | 67 | 57 |
Temperature deviation means conversion factor(as per 60364-5-52)
Ambient Temperature(°C) | Conversion Factor | Ambient Temperature(°C) | Conversion Factor | Ambient Temperature(°C) | Conversion Factor |
≤60 | 1.00 | ≤80 | 0.82 | ≤100 | 0.58 |
≤70 | 0.91 | ≤90 | 0.71 | ≤110 | 0.41 |