This cable is for fixed installation,used in control and signal system in ship.
-JISC 3410-1999/2010
-IEC 60092-350
-IEC 60332-1
-IEC 60332-3 Cat.AF(for FA-type)
Voltage rating: 250V
Maximum conductor temperature:85°C
Classification | Code | Construction details |
Conductor | M | Tinned Copper Wire JIS C3410 |
Insulation | P | EPR as per JIS C 3410 |
Common Shield | S | Tinned Copper Wire |
Sheath | Y | PVC as per JIS C 3410 |
Armor | C | Galvanized steel wire braided |
CB | Tinned copper wire braided | |
Paint | The white paint should be painted uniformly | |
Covering | Y | PVC as per JIS C 3410 |
Color: Black |
Installations recommendations
Minimum cable bending radius
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than :
6 times the external diameter of cable
Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations temperature
Minimum recommended temperature of installations :
-10°C Ship wiring cable with PVC sheath
-20°C Elastomeric on/off shore cables
Installations pulling force
The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.