Product Categories
- Marine Cable
- Marine Power Cable
- Marine Communication Cable
- Marine Control Cable
- Offshore Cable
- Crane Cable
- Mining Cable
- Electrical Cable
- Solar Cable
- Underwater Cable
- Wind Cable
This Cable can be applied in Marine&Offshore and various ships, ship repair and oil platforms and other offshore buildings control device and general electric lighting,machinery and equipment of factories and mines are also equally applicable.
– Design guide : JIS C 3410(1999/2010)
– Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
– Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
– Max. conductor temperature : 85℃
0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY
0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY
0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY
0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC
0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY
0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE
Conductor | T(S) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
Conductor screen | Semi-conducting compound | |
Insulation | P | 85°C EPR as per IEC 60092-351 |
Insulation screen | Semi-conducting compound /Tinned copper tape | |
Filler | Non-hygroscopic material (If necessary) | |
Bedding | Y | PVC,ST2 type |
Armor | C (CB) |
Galvanized steel wire braid(-C TYPE) or copper alloy wire braid(-CB TYPE) |
Sheath | Y | PVC ST2 type |
Core identification | 3C Red, Yellow, Blue | |
Outer sheath color | Red |
Installations recommendations
Minimum cable bending radius
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than :
6 times the external diameter of cable
Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations temperature
Minimum recommended temperature of installations :
-10°C Ship wiring cable with PVC sheath
-20°C Elastomeric on/off shore cables
Installations pulling force
The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation
and sheathing compound.