Two Cores PV1-F Solar Cable

Two Cores PV1-F Solar Cable

Two Cores PV1-F Solar Cable

TUV UV Resistant PV1-F Solar Cable Applications
Applied to  solar panels for power generation and related components of the wiring, connection,particularly suitable for outdoor . Resistance to sunlight, anti-aging , Using the low smoke halogen-free flame retardant materials, higher grade, more safety .

TUV UV Resistant PV1-F Solar Cable Executive Standard:
PV cable( Solar Photovoltaic Cable ) refers to original draft made out by PV system cable work team of German Standard Committee(Technical Specification 2PFG1169/08.2007 in Rhein TUV company German).

1, Rated voltage:
AC: U0 / U = 0.6/1kV
DC: 1.8kV (line core for core, non-grounded systems, no load circuit)
If the cable is used in the DC system, the rated voltage between the conductors of the cable should not exceed 1.5 times the AC rating of U.
In the single-phase DC systems, this value should be multiplied by the factor 0.5. Operating temperature -40 °C ~ 90 °C (with> 25 years)
2, ambient temperature: -40 °C to +90 °C
Maximum conductor operating temperature: 120 °C
Cable runs ambient temperature up to 90 °C. According to EN60216-1 standard for assessment, the insulation and jacket temperature index is 120 °C.
The life expectancy is 25 years
The short-circuit temperature is 5 seconds 200 °C
3, the short-circuit temperature +280 °C
4, does not melt under high temperature, no flow
5, high flame, through the vertical flame test
6, heat, cold, abrasion, UV, ozone, hydrolysis
7, has good mechanical strength, water,oil and chemical resistance

Cable Characteristics

MODEL                   PV1-F
Conductor Tinned copper wire,class 5 (as per IEC 60228)
Insulation No Halogen PO insulation
Sheath No Halogen PO sheath
rated voltage AC  0.6/1KV
DC  1.8KV
Temperature range -40°C~+90°C,dry/ humidity
Max.working temperature of conductor  120°C
During short circuit  200°C
Standard EN 2PFG 1169

Two Cores PV1-F Solar Cable Diagram

PV1-F  Structure Parameter 

  type Cross Sectional
Area(mm2)
Conductor structure
( Strand /mm)
diameter
(mm)
insulation
thickness
(mm)
sheath thickness
(mm)
cable diameter
(mm)
DC
resistance
at 20°C
(Ω/km)
PV1-F 1.5  48/0.2 1.6 1.0 0.8 5.2 12.2
PV1-F 2.5  77/0.2 2.0 1.0 0.8 5.6 7.56
PV1-F 4 56/0.3 2.6 1.0 0.9 6.4 4.7
PV1-F 6 84/0.3 3.2 1.0 0.9 7.0 3.11
PV1-F 10 77/0.41 4.4 1.0 0.9 8.2 1.84
 PV1-F 16 119/0.41 5.5 1.0 1.1 9.7  1.16
 PV1-F 25 189/0.41 6.5 1.2 1.2 11.3 0.734
PV1-F 35 244/0.41 7.5 1.2 1.2 12.3 0.529

Current Capacity Reference Value

(Ambient Temperture:60°C,Max. Conductor Working Temperature:120°C)

Nom.Area(mm2) Single core in the air(A) Single core on the equipmnt surface(A) Next to equipment(A)
1.5 30 29 24
2.5 41 39 33
4 55 52 44
6 70 67 57
10 98 93 79
16 132 125 107
25 176 167 142
35 218 207 176

Temperature deviation means conversion factor(as per 60364-5-52)

Ambient Temperature(°C) Conversion Factor Ambient Temperature(°C)  Conversion Factor Ambient Temperature(°C) Conversion Factor
 ≤60  1.00    ≤80  0.82    ≤100  0.58
 ≤70  0.91    ≤90  0.71    ≤110  0.41

 

Enquiry Form:

*
*
3 + 4 = ?
Please enter the answer to the sum & Click Submit to verify your registration.