Product Categories
- Marine Cable
- Marine Power Cable
- Marine Communication Cable
- Marine Control Cable
- Offshore Cable
- Crane Cable
- Mining Cable
- Electrical Cable
- Solar Cable
- Underwater Cable
- Wind Cable
Type SHD-CGC Shield Ground-check Power Cable 5KV
Type SHD-CGC Shield Ground-check Power Cable 5KV Application
These heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobile equipment requiring grounding conductors, where a ground check conductor, and metallic shielding are required
Designed for use as a trailing cable on AC mining equipment:
Where maximum safety is mandatory,including underground mining machines whereinduced voltages in an unbalanced groundingsystem could be hazardous
On low- and medium-voltage AC circuits where shielding is desired or required
Type SHD-CGC Shield Ground-check Power Cable 5KV Applied Standards
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
Type SHD-CGC Shield Ground-check Power Cable 5KV Constructions
Conductor:
1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation:
Ethylene Propylene Rubber (EPR) insulation
Insulation Shield:
A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape
Ground-Check Conductor:
Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex
fatigue Insulated with high-strength polypropylene and placed in the center interstice
Grounding Conductors:
Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield
Jacket:
Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Jacket:
Reinforced, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option
Mechanical and Thermal Properties
Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90℃
Type SHD Power Flat Portable Cable 2KV Features:
Flexible insulation shield provides shock hazard protection
Excellent heat, moisture, steam, oil, chemical and radiation resistance
Flexible for easy handling
Resists cutting, impact, abrasion, flame and sunlight
Excellent thermal stability and physical properties over a broad temperature range
Type SHD Power Flat Portable Cable 2KV Specifications
Construction |
No. of Strands |
Grounding Conductor Size |
Ground Check Conductor Size |
Nominal Insulation Thickness |
Nominal |
Nominal Overall Diameter |
Nominal Weight |
Ampacity |
||||
No. of cores×AWG/kcmil |
– |
AWG/kcmil |
AWG/kcmil |
inch |
mm |
inch |
mm |
inch |
mm |
lbs/kft |
kg/km |
A |
3×2/0 |
323 |
5 |
16 |
0.11 |
2.8 |
0.220 |
5.6 |
2.20 |
55.9 |
3716 |
5529 |
243 |
3×3/0 |
418 |
4 |
16 |
0.11 |
2.8 |
0.235 |
6.0 |
2.36 |
59.9 |
4130 |
6145 |
279 |
3×4/0 |
532 |
3 |
16 |
0.11 |
2.8 |
0.235 |
6.0 |
2.50 |
63.5 |
5190 |
7722 |
321 |
3×350 |
888 |
1 |
16 |
0.12 |
3.0 |
0.265 |
6.7 |
2.95 |
74.9 |
7571 |
11264 |
435 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.